American Standard 5A6H6 - 5 Ton - 15.2 SEER2/8.1 HSPF2 Heat Pump with S8X1 - Single-Stage - 80% AFUE Backup Furnace - Multi-Position Coil - Dual Fuel System - with install

    Description

    American Standard, offered by Lakewood Air, is a trusted name in home comfort, delivering high-performance HVAC systems that combine efficiency, reliability, and innovation. Focused on energy savings and durability, American Standard products meet top standards in residential heating and cooling. Whether upgrading or installing new, American Standard provides advanced solutions to keep your home comfortable year-round.

    What's Included:

    • American Standard 5A6H6060A Condenser: Positioned as the step-up 'Silver 15' single-stage heat pump above the 5A6H4, offering a wider efficiency range up to 15.2-16 SEER2 and 7.5-8.1 HSPF2 on R-454B refrigerant across 1.5-5 ton capacities. NOTE: could not verify the exact model prefix '5A6H6' in any official American Standard documentation; the verified official Silver 15 heat pump prefix is 5A6H5 -- please confirm the model numbering with your supplier before publishing.
    • American Standard S8X1C100M5PS Backup Furnace: The American Standard S8X1 is the wider-cabinet counterpart to the S8B1, an 80% AFUE single-stage gas furnace with aluminized-steel heat exchanger and ECM blower, built in a 21 in. wide cabinet for higher airflow / larger duct systems at the same BTU input range (40,000-100,000 BTU). Cabinet width (17.5 in for S8B1 vs 21 in for S8X1) is the primary distinguishing factor between the two series, not efficiency or staging.
    • 5TXC Cased Aluminum Evaporator Coil 5TXCC009AS Evaporator Coil: The American Standard 5TXC is an aluminum cased multi-position (upflow/downflow/horizontal) evaporator coil engineered for use with Silver-series condensers and heat pumps, sized 1.5-5 ton, compatible with R-454B refrigerant systems.

    Includes licensed and insured HVAC installation by professionals, along with the Install Kit for a complete setup.

    Professional Installation:

    • Removal & haul-off of existing equipment
    • Installation of new equipment and all included parts
    • Refrigerant line connection, evacuation & charge to OEM spec
    • Full system start-up, airflow check & operational testing
    • Permit pulled and permit fees paid with the local jurisdiction
    • Final inspection and job-site clean-up
    • Performed by a licensed, insured HVAC contractor

    Dual Fuel Kit (Heat Pump Condenser & Coil + Backup Furnace)

    • Electrical & mounting disconnect, A/C whip, condenser pad
    • Refrigerant line filter drier, locking caps, ArmaFlex insulation
    • Gas line gas flex hose, gas pipe fittings (nipples, unions, shut-off, drip leg)
    • Venting flue pipe & elbow set for furnace exhaust
    • Drainage & PVC P-trap, full PVC fittings kit (couplings, elbows, tee, adapters)

    Not Included:

    This listing covers the equipment and standard installation scope above. The following items are not included unless specifically listed on your written invoice or estimate:

    • Electrical panel upgrades or new breakers beyond the conventional disconnect
    • Ductwork modifications, repairs, replacement, or new runs
    • New refrigerant line set (existing line set is reused when in good condition)
    • Condenser pad re-pour, raised platform, or hurricane tie-downs (standard composite pad is included)
    • Condenser relocation to a new exterior position
    • Crane or rooftop rigging for difficult equipment access
    • Gas line extension, re-routing, or new gas line installation
    • Condensate drain line rework beyond the immediate connection at the unit
    • Thermostat upgrades (standard thermostat reuse only)
    • Asbestos abatement, mold remediation, or hazardous material handling
    • Carpentry, drywall, paint, or flooring repair after installation

    If any of the above are needed for your home, your technician will note it on your estimate before work begins.

    SPECIFICATIONS

    Bundle Size/Tonnage

    5 Ton

    Bundle Cooling Efficiency (SEER2)

    15.2 SEER2

    Condenser Model

    5A6H6060A

    Condenser Stages

    Single

    Furnace Model

    S8X1C100M5PS

    Furnace Stages

    Single-Stage

    Furnace Efficiency

    80%

    Coil Model

    5TXCC009AS

    Heat Source

    Gas

    AHRI

    218109425

    Refrigerant

    R-454B

    Warranty

    10 Year Parts, 10 Year Compressor (When Registered with OEM)

    RESOURCES
    Product form
    • American Standard

    American Standard 5A6H6 - 5 Ton - 15.2 SEER2/8.1 HSPF2 Heat Pump with S8X1 - Single-Stage - 80% AFUE Backup Furnace - Multi-Position Coil - Dual Fuel System - with install

      American Standard, offered by Lakewood Air, is a trusted name in home comfort, delivering high-performance HVAC systems that combine efficiency,... Read more

      $13,337.82

        • 10 Year Parts Warranty
        • 5 Year Labor Guarantee

        SKU: ALC-AS-DF-152-50-80-1S-MP-01

        Description

        American Standard, offered by Lakewood Air, is a trusted name in home comfort, delivering high-performance HVAC systems that combine efficiency, reliability, and innovation. Focused on energy savings and durability, American Standard products meet top standards in residential heating and cooling. Whether upgrading or installing new, American Standard provides advanced solutions to keep your home comfortable year-round.

        What's Included:

        • American Standard 5A6H6060A Condenser: Positioned as the step-up 'Silver 15' single-stage heat pump above the 5A6H4, offering a wider efficiency range up to 15.2-16 SEER2 and 7.5-8.1 HSPF2 on R-454B refrigerant across 1.5-5 ton capacities. NOTE: could not verify the exact model prefix '5A6H6' in any official American Standard documentation; the verified official Silver 15 heat pump prefix is 5A6H5 -- please confirm the model numbering with your supplier before publishing.
        • American Standard S8X1C100M5PS Backup Furnace: The American Standard S8X1 is the wider-cabinet counterpart to the S8B1, an 80% AFUE single-stage gas furnace with aluminized-steel heat exchanger and ECM blower, built in a 21 in. wide cabinet for higher airflow / larger duct systems at the same BTU input range (40,000-100,000 BTU). Cabinet width (17.5 in for S8B1 vs 21 in for S8X1) is the primary distinguishing factor between the two series, not efficiency or staging.
        • 5TXC Cased Aluminum Evaporator Coil 5TXCC009AS Evaporator Coil: The American Standard 5TXC is an aluminum cased multi-position (upflow/downflow/horizontal) evaporator coil engineered for use with Silver-series condensers and heat pumps, sized 1.5-5 ton, compatible with R-454B refrigerant systems.

        Includes licensed and insured HVAC installation by professionals, along with the Install Kit for a complete setup.

        Professional Installation:

        • Removal & haul-off of existing equipment
        • Installation of new equipment and all included parts
        • Refrigerant line connection, evacuation & charge to OEM spec
        • Full system start-up, airflow check & operational testing
        • Permit pulled and permit fees paid with the local jurisdiction
        • Final inspection and job-site clean-up
        • Performed by a licensed, insured HVAC contractor

        Dual Fuel Kit (Heat Pump Condenser & Coil + Backup Furnace)

        • Electrical & mounting disconnect, A/C whip, condenser pad
        • Refrigerant line filter drier, locking caps, ArmaFlex insulation
        • Gas line gas flex hose, gas pipe fittings (nipples, unions, shut-off, drip leg)
        • Venting flue pipe & elbow set for furnace exhaust
        • Drainage & PVC P-trap, full PVC fittings kit (couplings, elbows, tee, adapters)

        Not Included:

        This listing covers the equipment and standard installation scope above. The following items are not included unless specifically listed on your written invoice or estimate:

        • Electrical panel upgrades or new breakers beyond the conventional disconnect
        • Ductwork modifications, repairs, replacement, or new runs
        • New refrigerant line set (existing line set is reused when in good condition)
        • Condenser pad re-pour, raised platform, or hurricane tie-downs (standard composite pad is included)
        • Condenser relocation to a new exterior position
        • Crane or rooftop rigging for difficult equipment access
        • Gas line extension, re-routing, or new gas line installation
        • Condensate drain line rework beyond the immediate connection at the unit
        • Thermostat upgrades (standard thermostat reuse only)
        • Asbestos abatement, mold remediation, or hazardous material handling
        • Carpentry, drywall, paint, or flooring repair after installation

        If any of the above are needed for your home, your technician will note it on your estimate before work begins.

        SPECIFICATIONS

        Bundle Size/Tonnage

        5 Ton

        Bundle Cooling Efficiency (SEER2)

        15.2 SEER2

        Condenser Model

        5A6H6060A

        Condenser Stages

        Single

        Furnace Model

        S8X1C100M5PS

        Furnace Stages

        Single-Stage

        Furnace Efficiency

        80%

        Coil Model

        5TXCC009AS

        Heat Source

        Gas

        AHRI

        218109425

        Refrigerant

        R-454B

        Warranty

        10 Year Parts, 10 Year Compressor (When Registered with OEM)

        RESOURCES

        Recently viewed products

          Footer image

          © 2026 Lakewood Air LLC

            • American Express
            • Apple Pay
            • Diners Club
            • Discover
            • Google Pay
            • Mastercard
            • PayPal
            • Shop Pay
            • Visa

            Login

            Forgot your password?

            Don't have an account yet?
            Create account